Air Source Heat Pump cost data

Data point Valid in Capital cost Operating cost excluding fuel Source
£(2010)/KW £(2010)/KW
  Domestic 2010 625–2150 ? CCC
  Commercial 2010 538–635 ? CCC
  Domestic - 14KW 2009 650–750 4 NERA & AEA
  Commercial/Public (small) 2009 561 6 NERA & AEA
  Commercial/Public (large) 2009 628 1 NERA & AEA
  Industrial (small) 2009 628 1 NERA & AEA
  Industrial (large) 2009 628 1 NERA & AEA
  Domestic - 6KW 2009 1400–1650 9 NERA & AEA
  Domestic - 14KW 2020 468–594 4 NERA & AEA
  Commercial/Public (small) 2020 432 6 NERA & AEA
  Commercial/Public (large) 2020 483 1 NERA & AEA
  Industrial (small) 2020 483 1 NERA & AEA
  Industrial (large) 2020 483 1 NERA & AEA
  Domestic - 6KW 2020 1109–1308 9 NERA & AEA
  Representative Cost per home 2010 617–772 4–9 NERA & AEA
  Domestic 2010 600–772 4–9 2050 working assumption
  Non-Domestic 2010-2050 1236–1797 2–18 2050 working assumption
  Domestic 2050 328–772 4–9 2050 working assumption
  Heat Pumps 2010-2050 7357 30 Markal 3.24
Range 2009-2050 328–7357 1–30  

Notes

What should be included in this category?

Investment cost of the technology and installation of a heat pump. Note, all costs are in KW of heat delivered net of conversion losses.

What should be excluded from this category?

Non-market costs, such as hassle costs

How are these costs used in the 2050 Pathways model?

Domestic - Assume an average installation size of 14KW per household and use the investment cost per kw to derive a cost of a heat pump per household. Please see: IX.a Domestic space heating and hot water costs for the full methodology

Commercial - Multiply the investment cost per kw by the load factor (typical annual average output) then uprate to give a cost per TWh (annual) of meeting commercial heating demand. This figure is then multiplied by 2 to account for peak load. Please see: IX.C COMMERCIAL HEATING AND COOLING COSTS for the full methodology

Other sets of cost data

Air Conditioning Air Source Heat Pump Air Source Heat Pump with Storage (commercial) Air Source Heat Pump with Storage (domestic) Battery Storage Biogas Biomass 1st generation biocrops Biomass 2nd generation biocrops Biomass Boiler (commercial) Biomass conversion 1st generation energy crops to liquid Biomass conversion 2nd generation energy crops to gas Biomass conversion 2nd generation energy crops to liquid Biomass conversion dry biomass and waste to gas Biomass conversion dry biomass and waste to liquid Biomass conversion dry biomass, biocrops and waste to solid Biomass conversion gas to gas Biomass conversion wet biomass and waste to gas Biomass conversion wet biomass and waste to liquid Biomass forestry arisings collection Biomass liquid fuel imports Biomass manure collection Biomass solid fuel imports Biomass straw collection Biomatter to fuel conversion Bus EV Bus Hybrid EV Bus Hydrogen FCV Bus ICE Carbon Storage Cars EV Cars Fuel Cell Vehicle Cars ICE Cars PHEV Cavity wall insulation CHP Coal CCS Coal-fired Boiler Coal Price Commercial cooking demand reduction Commercial Heat Demand Commercial lighting and appliances Compressed Air storage Conventional Coal Electricity Generation Conventional Gas Electricity Generation Cooking District Heating (domestic) District Heating Network Draughtproofing Electric heating Electricity Distribution Electricity Grid Distribution Costs Electricity Grid Transmission Costs Electricity Transmission Energy Saving Trust’s Advanced Practice Energy Efficiency standard for New Build Enteric fermentation abatement Exported Electricity Floor insulation Fossil Fuel Transfer Costs Gas Boiler Gas CCS Electricity Generation Gas (Natural or Biogas) CHP Gas Price Geosequestration Geothermal Electricity Geothermal Heat Ground Source Heat Pump (commercial) Ground Source Heat Pump Ground Source Heat Pump with Storage (commercial) Ground Source Heat Pump with Storage (domestic) Heat exchanger for District heating Hydroelectricity Hydro pumped storage Imported Electricity Imported Uranium Interconnection International Aviation International Shipping Loft Insulation Macro Algae Manure management Micro CHP Microwind Nuclear Power Offshore Wind Oil Electricity Generation plants Oil-fired boiler Oil fired Boiler Oil Price Onshore Wind Passenger Rail Passiv Haus Pumped storage - Hydro Rail Freight Range - Cars ICE Road Freight Soil management Soil management level 1 Solar PV Solar Thermal (commercial) Solar Thermal Solid Biomass Electricity Generation 2050 Solid Biomass Electricity Generation Solid Fuel Boiler (inc Biomass) Solid Fuel CHP Solid wall insulation Conventional Oil Electricity Generation Temporary Superglazing Test category Tidal Range Tidal Stream UK National Aviation UK National Shipping Uranium Enrichment & Disposal Waste collection and separation Waste landfill gas capture Waste landfill sites Waste sewage gas capture Wave