Data point | Valid in | Capital cost | Operating cost excluding fuel | Source | |
---|---|---|---|---|---|
£(2010)/kWpeak | £(2010)/kWpeak | ||||
MottMacDonald (2011) | 2010 | 4016–5434 | 114–178 | MottMacDonald (2011) | |
MottMacDonald (2011) | 2050 | 2428–3584 | 85–137 | MottMacDonald (2011) | |
2050 Range | 2050 | 2141–7848 | 85–258 | 2050 working assumption | |
Geothermal Plant | 2010 | 2681–7680 | 142–255 | Arup/EY | |
Geothermal Plant | 2015 | 1998–5723 | 142–256 | Arup/EY | |
Geothermal Plant | 2020 | 1957–5606 | 143–257 | Arup/EY | |
Geothermal Plant | 2025 | 1903–5450 | 143–257 | Arup/EY | |
Geothermal Plant | 2030 | 1852–5304 | 144–258 | Arup/EY | |
2010 Range | 2010 | 4016–7848 | 85–258 | 2050 working assumption | |
Range | 2010-2050 | 1852–7848 | 85–258 |